PS5305 Illegal Spindle Number
In a spindle select function by address P for a multiple spindle control: 1) Address P is not specified. 2) A P code for selecting a spindle is not set in parameter No. 3781. 3) An illegal G code which cannot be commanded with an S_P_; command is specified. 4) Multi-spindle control is not enabled because bit 1 (EMS) of parameter No. 3702 is 1. 5) The spindle amplifier number of each spindle is not set in parameter No. 3717. 6) A spindle command is executed from a path in which this command is prohibited (parameter No. 11090). 7) The setting of parameter No. 11090 is incorrect. Verify parameters are set correctly. Modify the program.
Quick tip:
Verify parameters set correctly or modify program.