1. Home
  2. Knowledge Base
  3. Counter Rotating Spindles

Counter Rotating Spindles

In order to counter rotate spindles on a TCM S machine you need to check the following.

Keep Relay 2.3 Can be rotated the Cross or back live tool when CS mode is not on

0: Disabled

1: Enabled (When using this function, K3.0 must be set to 0)

Program example:

T3232 M123 S3000

M103S3000

G0Z.1

G98G1Z-1.F30.