The axis specified in automatic zero return was not at the correct zero point when positioning was completed. Perform zero return from a point whose distance from the zero return start position to the zero point is 2 or more revolutions of the motor. Other probable causes are: 1) The positional deviation after triggering the deceleration dog is less than 128. 2) Insufficient voltage or malfunctioning pulse coder.

 

Quick tip;

Perform zero return from a point whose distance from the zero return start position to the zero point is 2 or more revolutions of the motor.

 