DS1448 Illegal Parameter (D.C.S.)

  1. Home
  2. Knowledge Base
  3. TCM S Machine
  4. Alarm
  5. DS1448 Illegal Parameter (D.C.S.)
  1. Home
  2. Knowledge Base
  3. TCM S Machine
  4. DS1448 Illegal Parameter (D.C.S.)

The setting value of parameter for reference marks is satisfied the following any conditions. 1) A setting is made to use the absolute position detector (bit 5 APC of parameter No. 1815 is 1). 2) Either parameter No. 1821 (mark-1 interval) or parameter No. 1882 (mark-2 interval) is set to 0. 3) Parameters Nos. 1821 and 1882 have identical settings. 4) The difference between the settings made for parameter No. 1821 and No. 1882 is greater than or equal to twice either setting. 5) The setting value of parameter No. 1883 and No. 1884 are over the valid data range.

Quick tip:

Set parameters correctly.