(T Series) This error occurred when: 1) A move command was executed for an axis for which bit 7 (NUMx) of parameter No. 8163 was 1. 2) A move command was executed for a slave axis in synchronous control. 3) A move command was executed for an axis for which bit 7 (MUMx) of parameter No. 8162 was 1 in composite control. Check parameter settings and program.

 

Quick tip:

Check parameter settings and program.

 