- Home
- Knowledge Base
- TCM S Machine
- Alarm
Alarm
SP9051 SSPA:51 Low Voltage DC Link
Input voltage drop was detected (PSM alarm indication: 04). Momentary power failure or poor MC contact. Check and correct the...
SP9052 SSPA:52 ITP Signal Abnormal
NC interface abnormality was detected (the ITP signal stopped). Replace the SPM control pcb or the spindle interface pcb in...
SP9053 SSPA:53 ITP Signal Abnormal II
NC interface abnormality was detected (the ITP signal stopped). Replace the SPM control pcb or the spindle interface pcb in...
SP9054 SSPA:54 Overload Current
An overload current was detected. Review the load state (applications). Quick tip: Review the load state
SP9055 SSPA:55 Power Line Switch Error
The power line state signal of the magnetic contactor for selecting a spindle or output is abnormal. Replace the magnetic...