Alarm

SP9065 Serial Spindle Alarm

The move distance is too long when the magnetic pole is confirmed (synchronization spindle). Check parameter settings. Check sensor connections...

SP9066 Amplifier Module Communication

An error was found in communication between amplifiers (connector JX4). Check and correct the connections. Replace the cable.   Quick...

SP9069 Safety Speed Over

In the state in which safety speed monitoring was enabled, the system detected that the motor speed exceeded the safety...

SP9070 Illegal Axis Data

The spindle amplifier connection state conflicts with the amplifier setting. Setting the spindle amplifier side to conform to the connection...

SP9071 Safety Parameter Error

An error was detected in an axis parameter check. Input the safety parameter again. Replace the spindle amplifier control printed...