SP9088 Cooling Radiator Fan Failure
The external cooling fan stopped. Replace the SPM external cooling fan. Quick tip: Replace fan
SP9089 Cooling Radiator Fan Failure
Submodule SM (SSM) error (Synchronous Spindle). Check the connections between the spindle amplifier and the submodule SM (SSM). Replace the...
SP9090 Serial Spindle Alarm
Abnormal rotation of the synchronous spindle motor was detected. Check magnetic pole detection operation. Check whether the rotor and sensor...
SP9091 Serial Spindle Alarm
Count error of the magnetic pole position of the synchronous spindle motor. Replace the motor sensor cable. Quick tip:...
SP9092 Serial Spindle Alarm
The motor speed exceeds the acceleration level corresponding to the velocity command. Check the sequence (whether SFR or SVR is...