Alarm

SP9113 Converter Cooling Fan Failure (b3 on SPM)

Stopped cooling fan of the converter radiator (PSM alarm indication: A, SPM alarm indication: b3). Replace the radiator cooling fan...

SP9120 Communication Data Error (C0 on SPM)

Communication data alarm (SPM alarm indication: C0). Replace the communication cable between the CNC and SPM. Replace the SPM control...

SP9121 Communication Data Error (C1 on SPM)

Communication data alarm (SPM alarm indication: C1). Replace the communication cable between the CNC and SPM. Replace the SPM control...

SP9122 Communication Data Error (C2 on SPM)

Communication data alarm (SPM alarm indication: C2). Replace the communication cable between the CNC and SPM. Replace the SPM control...

SP9123 Serial Spindle Alarm (C3 on SPM)

Submodule SW (SSW) error (spindle switching). Replace the submodule SW (SSW).   Quick tip: Replace the submodule.