Alarm
OT0503- Over Travel (2nd Stored Stroke)
Exceeded the negative side second stored stroke limit set by parameter No. 1323. Note: only active when parameter No. 1310#0...
OT0504+ Over Travel (3rd Stored Stroke)
Exceeded the positive side third stored stroke limit set by parameter No. 1324. Note: only active when parameter No. 1310#1...
OT0505 Over Travel (3rd Stored Stroke)
Exceeded the negative side third stored stroke limit set by parameter No. 1325. Note: only active when parameter No. 1310#1...
DS0132 Message Number Not Found
An attempt to cancel an external operator message or external alarm message failed because the specified message number was not...
OT0506+ Over Travel (Hardware)
Exceeded positive side hardware OT. This alarm is generated when the machine reaches the stoke end. When this alarm is...