PS0045 Address Q Not Found (G73/G83)
In a high-speed peck drilling cycle or peck drilling cycle, the amount of each-time cutting is not specified by address...
PS0046 Illegal Reference Return Command
A command for a return to the second, third or fourth reference position is error (the address P command is...
PS0050 Chamfer/Corner Round Not Allowed in Thread Block
The chamfering or corner R block is specified in a threading block. Modify the program. Quick tip: Modify program
PS0051 Missing Move After Chamfer/Corner Round
The travel or travel distance is incorrect in the block next to the chamfering or corner R. Modify the program....
PS0052 Code is Not G01 After Chamfer/Corner Round (T Series)