- Home
- Knowledge Base
- TCM S Machine
- Alarm
Alarm
PS0376 Serial DCL: Illegal Parameter
1) When parameter No. 1815#1 is set to “1”, parameter No. 2002#3 is set to “0”. 2) The absolute-position detection...
PS0412 Illegal G Code
An unusable G code was used. Modify program. Alternatively, the option for that G code is not installed. Contact FANUC...
PS0445 Illegal Axis Operation (T Series)
(T Series) The positioning command was issued in the speed control mode. Check the SV speed control mode signal (Fn521)....
PS0446 Illegal Command in G96.1/G96.2/G96.3/G96.4 (T Series)
(T Series) G96.1, G96.2, G96.3, and G96.4 are specified in the block that includes other commands. Modify the program. ...
PS0447 Illegal Setting Data
The spindle controlled with the servo motor is not set correctly. Check the parameters for the function of spindle control...