TCM S Machine

Alarm

728 Articles

Prints

4 Articles

SP9018 SSPA:18 Sumcheck Error PGM Data

Abnormality in an SPM control circuit component is detected (program ROM data is abnormal). Replace the SPM control printed circuit...

SP9018 SSPA:18 Sumcheck Error PGM Data

Abnormality in an SPM control circuit component is detected (program ROM data is abnormal). Replace the SPM control printed circuit...

SP9019 SSPA:19 Excessive Offset Current U-phase

Abnormality in an SPM component is detected (the initial value for the U-phase current detection circuit is abnormal). Replace the...

SP9020 SSPA:20 Excessive Offset Current V-phase

Abnormality in an SPM component is detected (the initial value for the V-phase current detection circuit is abnormal). Replace the...

SP9021 SSPA:21 Position Sensor Polarity Error

The polarity parameter setting of the position sensor is wrong. Check and correct the parameters (Nos. 4000#0, 4001#4).   Quick...