TCM S Machine

Alarm

728 Articles

Prints

4 Articles

SP9058 Overload in PSM

An overload was detected in the regenerative resistance (PSMR alarm indication: 08). Thermostat operation or short-time overload was detected. The...

SP9059 Cooling Fan Stop in PSM

The cooling fan in the PSM has stopped (PSM alarm indication: 02). Replace the internal fan in PSM.   Quick...

SP9061 Serial Spindle Alarm

The error between the semi-closed and full-closed sides when the dual position feedback function is used is too large. Check...

SP9065 Serial Spindle Alarm

The move distance is too long when the magnetic pole is confirmed (synchronization spindle). Check parameter settings. Check sensor connections...

SP9066 Amplifier Module Communication

An error was found in communication between amplifiers (connector JX4). Check and correct the connections. Replace the cable.   Quick...