SP9121 Communication Data Error (C1 on SPM)
Communication data alarm (SPM alarm indication: C1). Replace the communication cable between the CNC and SPM. Replace the SPM control...
SP9122 Communication Data Error (C2 on SPM)
Communication data alarm (SPM alarm indication: C2). Replace the communication cable between the CNC and SPM. Replace the SPM control...
SP9123 Serial Spindle Alarm (C3 on SPM)
Submodule SW (SSW) error (spindle switching). Replace the submodule SW (SSW). Quick tip: Replace the submodule.
SP9133 Serial Spindle Alarm (d3 on SPM)
Data transfer error. Replace the sensor. Quick tip: Replace the sensor.
SP9134 Serial Spindle Alarm (d4 on SPM)
Soft phase error. Check and correct the sensor parameter setting. Take action against noise. Replace the sensor. Quick tip:...