SP9135 Safety Speed Zero Error (SP) (d5 on SPM)
The motor position exceeded the safety speed zero monitoring width. Perform operation within the safety speed zero range. Quick tip:...
SP9136 Mismatch Result of Safety Speed Zero Check (SP) (d6 on SPM)
The spindle amplifier speed zero determination result did not match the CNC speed zero determination result. Replace the spindle amplifier...
SP9137 Serial Spindle Alarm (d7 on SPM)
Device communication error. Replace the spindle amplifier control printed circuit board. Quick tip: Replace the spindle amplifier control pcb.
SP9139 Serial Spindle Alarm (d9 on SPM)
Pulse error. Replace the sensor. Quick tip: Replace the sensor.
SP9140 Serial Spindle Alarm (E0 on SPM)
Count error. Take action against noise. Replace the sensor. Quick tip: Check for noise and correct. Replace the sensor.