M3 Main spindle Clockwise
M3- (M)Main spindle (#1) forward (CW) rotation “M3 S1000” 10000 RPM max. M03- Can only be programmed from Main. To...
M4 Main spindle counter clockwise
M4- (M)Main spindle (#1) reverse (CCW) rotation “M4 S500” 8000 RPM max. M04- Can only be programmed from Main Sample...
M5 Main Spindle Stop
M5- (M)Main spindle (#1) stop M05-
M7 Auto Cutoff
M7-(M) Auto Cutoff Program. The previous machines used a M98P9000 to do this. I recommend continuing to use O9000 if...
M8 Coolant on
M8- (M&S)Coolant on M08- It takes time for coolant to reach the tool. Confirm coolant flow with M67.