PS0251 Tool Change Illegal T Command
An unusable T code was specified in M06Txx. Correct the program. Quick tip: Correct program.
PS0300 Illegal Command In Scaling
An illegal G code was specified during scaling. Modify the program. Quick tip: Modify program
PS0301 Resetting of Reference Return is Inhibited
Although parameter No. 1012#0 (IDGx) was set to 1 to inhibit the reference position from being set again for a...
PS0302 Setting the Reference Position Without Dog is not Performed
The reference position could not be set for a return to the reference position without a dog. Possible causes are:...
PS0304 G28 is Commanded Without Zero Return