PS1142 Too Long V-Name (SETVN)
The variable name used in a SETVN statement in a custom macro exceeds 8 characters. Modify the program. Quick...
PS1143 BPRNT/DPRNT Statement Format Error
The format used in the BPRINT statement or DPRNT statement is in error. Modify the program. Quick tip: Modify...
PS1144 G10 Format Error
Data input for the L No. of G10 or the corresponding function is not enabled. Data setting address P or...
PS1160 Command Data Overflow
An overflow occurred in the position data within the CNC. This alarm is also generated if the target position of...
PS1180 All Parallel Axes in Parking (T Series)
(T Series) All of the axis specified for automatic operation are parked. Use correct procedure. Quick tip: Use correct...