SP9035 SSPA:35 Excessive Setting Gear Ratio
Gear ratio data exceeding the allowable limit is set. Correct the value according to the parameter manual. Quick tip:...
SP9036 SSPA:36 Overflow Error Counter
An error counter overflow occurred. Check whether the position gain value is too large and correct the value. Quick...
SP9037 SSPA:37 Speed Detect Parameter Error
The setting of the parameter for the number of pulses in the speed detector is incorrect. Correct the value according...
SP9041 SSPA:41 1-Rotation Position Coder Error
The 1-Rotation signal of the spindle position coder (connector JY4) or the 1-Rotation of the MZ or BZ sensor (connector...
SP9042 SSPA:42 No 1-Rotation Position Coder Detect
The differential speed position coder signal (connector JY8) in SPM type 3 is abnormal. Replace the cable. Quick tip:...