SV0384 Soft Phase Alarm (Ext)
The digital servo software detected abnormal data on the separate detector. Replace the separate detector unit. Quick tip: Replace...
SV0385 Serial Data Error (Ext)
The communications data could not be received from the separate detector. Check the separate detector, cabling, SDU. Replace faulty component....
SV0386 Data Transfer Error (Ext)
A CRC error or stop bit error occurred in the communications data from the standalone detector. Check the separate detector,...
SV0387 Abnormal Encoder (Ext)
An abnormality occurred on a separate detector. For more information, contact the scale manufacturer. Quick tip: Contact the scale...
SV0401 Improper V-Ready Off
Although the ready signal (PRDY) of the position control was ON, the ready signal (VRDY) on the velocity control was...