- Home
- Knowledge Base
- TCM S Machine
- Alarm
Alarm
PS0203 Program Miss at Rigid Tapping
In rigid tap, position for a rigid M-Code (M29) or an S command is incorrect. Modify the program. ...
PS0204 Illegal Axis Operation
In rigid tap, an axis movement is specified between the rigid M-code (M29) block and G84 (or G74) block. Modify...
PS0201 Feedrate Not Found in Rigid Tap
The command F code for a cutting feedrate is a zero. If the value of F command is much smaller...
PS0205 Rigid Mode DI Signal Off
Although a rigid M code (M29) is specified in rigid tapping, the rigid mode DI signal (Dgn G061.0) is not...
PS0206 Can Not Change Plane (Rigid Tap)
Plane changeover was instructed in the rigid mode. Modify the program. Quick tip: Modify program.