SP9007 SSPA:07 Overspeed

The motor speed has exceeded 115% of its rated speed. When the spindle axis was in position control mode, positional...

SP9009 SSPA:09 Overheat Main Circuit

Abnormal temperature rise of the power transistor radiator. Improve the heat sink cooling status. If the heat sink cooling fan...

SP9010 SSPA:10 Low Volt Input Power

A drop in the input power voltage in the spindle amplifier is detected. Replace the cables. Replace the spindle amplifier...

SP9011 SSPA:11 Overvoltage Power Circuit

Overvoltage of the DC link section of the PSM was detected (PSM alarm indication: 7). PSM selection error (the maximum...

SP9012 SSPA:12 Overcurrent Power Circuit

The motor output current is abnormally high. A motor-specific parameter does not match the motor model. Or poor motor insulation....