TCM S Machine

Alarm

728 Articles

Prints

4 Articles

SP9022 Serial Spindle Alarm

A spindle amplifier overload current was detected. Review operation conditions (acceleration/deceleration and cutting) to reduce the load. Check and correct...

SP9024 SSPA:24 Serial Transfer Error

The CNC power is turned off (normal power-off or broken cable). An error is detected in communication data transferred to...

SP9027 SSPA:27 Disconnect Position Coder

The spindle position coder (connector JY4) signal is abnormal or the signal amplitude (connector JY2) of the MZ or BZ...

SP9029 SSPA:29 Short Time Overload

Excessive load has been applied continuously for a certain period of time (this alarm is issued also when the motor...

SP9030 SSPA:30 Overcurrent Power Circuit

Overcurrent is detected in PSM main circuit input (PSM alarm indication: 01). Unbalanced power supply. PSM selection error (the maximum...