TCM S Machine

Alarm

728 Articles

Prints

4 Articles

SP9037 SSPA:37 Speed Detect Parameter Error

The setting of the parameter for the number of pulses in the speed detector is incorrect. Correct the value according...

SP9041 SSPA:41 1-Rotation Position Coder Error

The 1-Rotation signal of the spindle position coder (connector JY4) or the 1-Rotation of the MZ or BZ sensor (connector...

SP9042 SSPA:42 No 1-Rotation Position Coder Detect

The differential speed position coder signal (connector JY8) in SPM type 3 is abnormal. Replace the cable.   Quick tip:...

SP9043 SSPA:43 Disconnect Position Coder for Differential Speed Mode

The differential speed position coder signal (connector JY8) in SPM type 3 is abnormal. Replace the cable.   Quick tip:...

SP9046 SSPA:46 Screw 1-Rotation Position Coder Alarm

An abnormality equivalent to alarm 41 was detected during thread cutting operation. Check and correct the parameter. Check signals from...