- Home
- Knowledge Base
- TCM S Machine
TCM S Machine
SP9047 SSPA:47 Position Coder Signal Abnormal
The A/B phase signal of the spindle position coder (connector JY4) or the A/B phase signal of the MZ or...
SP9049 SSPA:49 High Converted Differential Speed
In differential speed mode, the speed of the other spindle converted to the speed of the local spindle has exceeded...
SP9050 SSPA:50 Spindle Control Overspeed
In spindle synchronization, the speed command calculation value exceeded the allowable limit (the motor speed is calculated by multiplying the...
SP9051 SSPA:51 Low Voltage DC Link
Input voltage drop was detected (PSM alarm indication: 04). Momentary power failure or poor MC contact. Check and correct the...
SP9052 SSPA:52 ITP Signal Abnormal
NC interface abnormality was detected (the ITP signal stopped). Replace the SPM control pcb or the spindle interface pcb in...