SP9080 Alarm at the Other SP Amplifier
During inter-spindle amplifier communication, an alarm was generated on the remote spindle amplifier. Remove the cause of the alarm of...
SP9081 1-Rotation Motor Sensor Error
The 1-Rotation signal of the motor sensor cannot be correctly detected. Verify parameters are correct. Check signals from the sensor....
SP9082 No 1-Rotation Motor Sensor
The 1-Rotation signal of the motor sensor is not generated. Check signals from the sensor. Adjust if necessary. If no...
SP9083 Motor Sensor Signal Error
An irregularity was detected in a motor sensor feedback signal. Check signals from the sensor. Verify no noise on line....
SP9084 Spindle Sensor Disconnected
The spindle sensor feedback signal is not present. Check for shield ground on feedback cable. Check signals from the sensor....