PS0205 Rigid Mode DI Signal Off
Although a rigid M code (M29) is specified in rigid tapping, the rigid mode DI signal (Dgn G061.0) is not...
PS0206 Can Not Change Plane (Rigid Tap)
Plane changeover was instructed in the rigid mode. Modify the program. Quick tip: Modify program.
PS0207 Rigid Data Mismatch
The specified distance was too short or too long in rigid tapping. Correct the program. Quick tip: Correct program
PS0210 Can Not Command M198/M199
1) The execution of an M198 or M99 command was attempted during scheduled operation. Alternatively, the execution of an M198...
PS0213 Illegal Command in Synchro-Mode