M29-(M&S) Rigid Tap Mode ON

Sample Code:
T909M50
G28H0M23S600
G0X.75Z1.
M29S600
G88X0R-.05F.025
H120.
H120.
G80
M100
G0X2.M25T0M25
M51

New TCM Oitf program
T909M50
G28H0
G0G99X.75Z1.C0
G184X0F.025S600(Note spindle speed)
H120.
H120.

M100(Cancel G184)
G0X2.T0M25
M51

Note: must be in G99 mode.
Sometimes get a DI/D0 alarm in handle trace on older machines with 18itb control